Skip to content

Linear analysis

Analysis → Linear Analysis… (⌘L / Ctrl+L) linearizes the model from a top-level In block to an Out block.

  1. Add an In block where the input of the system is (e.g. the throttle command) and an Out block at the output (e.g. engine speed).
  2. Choose the operating point: the initial states, or the steady state (trim) for the In blocks' values.
  3. Press Linearize.

You get the transfer function, the poles (and whether the system is stable), the DC gain, a Bode plot, the gain and phase margins, and the step response.

The margins treat G(s) as the open loop of a unity-feedback system. To analyse a control loop, put the In block at the controller input (the error), the Out block at the plant output, and leave the loop open. A rule of thumb for a robust loop: a phase margin of at least 45° and a gain margin of at least 6 dB.

The Step response tab shows G and the closed loop G / (1 + G). Nyquist draws G(jω) (solid for positive, dashed for negative frequencies): for a stable open loop, the closed loop is stable when the curve does not encircle −1. Root locus shows the closed-loop poles of k·G(s) as k grows from 0: from the open-loop poles (×) to the zeros (○) or infinity.

PID tuning

The PID Tuning tab needs no In or Out blocks. Choose a PID Controller (or Discrete PID) block, PI or PID, and a phase margin, then press Tune. Nervus opens the loop at the block's output, linearizes the plant the controller sees, and shapes the loop: a PI has its zero at ωc/4 (Ti = 4/ωc), a PID also a derivative with Td = Ti/4 filtered at 10·ωc. It picks the fastest crossover ωc that keeps the phase margin, at least 6 dB gain margin and a stable closed loop, limited to 2π/(20·Ts) for a discrete controller; spare margin is used for faster integral action. The plot compares the closed-loop step responses with the current and tuned gains.

Apply to Block writes the gains; a gain given as a workspace variable (P = Kp) changes the variable. The tuned gains are a robust starting point. Discrete blocks with state (filters, delays) cut the loop while the plant is linearized.

From Python: nervus.analysis.linearize, trim, LinearModel.bode() / .margins() / .nyquist() / .root_locus(), and plant_at + tune_pid for PID tuning.