Skip to content

Tutorial: Exchanging models with FMI

You will learn FMI 2.0 co-simulation FMUs: exporting a subsystem, running it in another tool (fmpy, Simulink), importing an FMU as a block, and the communication-step delay of co-simulation
Before this From model to ECU C code
Level and time intermediate, about 30 minutes
Follow along start the editor (uv run nervus), File ▸ Open examples/fmi_plant.nervus, press ▶ and double-click the scopes; the figures below come from the same model
Topic ECU software, communication and diagnostics ▸ From model to ECU code (all tutorials)

FMI (Functional Mock-up Interface) is the standard for exchanging simulation models between tools. A model is packed as an FMU, a zip file with a description of its variables and compiled code, and almost every simulation tool can run one: Simulink (the FMU block), Dymola, OpenModelica, SimulationX, CANoe, AMESim, and Python with fmpy. This is how a Nervus model reaches a colleague's Simulink model, and how a supplier's plant model gets into Nervus.

uv sync --extra fmi
uv run python examples/fmi_exchange.py

Step 1: export an FMU

Open examples/throttle_ecu.nervus, select the ECU subsystem and choose Code ▸ Export FMU…. Nervus generates the C code (as in the code-generation tutorial), adds the FMI 2.0 functions around it, compiles it for this computer and writes ECU.fmu:

In the FMU From the model
inputs target_deg, tps_deg the subsystem's In blocks
output duty_pct the Out block
tunable parameters Kp, Ki, ... the calibratable workspace variables and block parameters
default communication step 0.01 s the ECU's task period
binaries/darwin64 (or linux64, win64) the compiled library for this computer
sources/ the C code, so the FMU can be built on other platforms

It is a co-simulation FMU: the importing tool calls it every communication step (a whole number of 10 ms periods), and the FMU runs the generated step function. The generated code keeps its state in global variables, so one program can run one instance of it at a time.

Step 2: run it without Nervus

The example runs the FMU in fmpy, without any Nervus code: a step of the target angle from 5° to 60° gives a duty cycle of 0 % before the step and 82 % after it, the same numbers as the model. In Simulink, drag an FMU block into a model and pick ECU.fmu; in Python:

from fmpy import simulate_fmu

result = simulate_fmu("ECU.fmu", stop_time=1.0, input=signals, start_values={"Kp": 3.0})

Step 3: import an FMU

The FMU block (Ports & Subsystems library) runs any FMI 2.0 co-simulation FMU in a Nervus model. Its ports are the FMU's inputs and outputs; parameters sets the FMU's parameters, for example Kp = 3.0; sample_time is the communication step (0: the FMU's default). examples/fmi_plant.nervus is the throttle model with the ECU subsystem replaced by the FMU:

The responses differ during the fast tip-in by up to 13°, and peak and steady state are the same. The reason is the co-simulation itself: the FMU's output is available at the end of a communication step, so the controller acts 10 ms later than the inline subsystem. That is true for every co-simulation FMU, also in Simulink; a shorter communication step (when the FMU allows it) makes the difference smaller.

Experiments

Try What you will see
ECU_fmu parameters = Kp = 3.0 a stiffer controller inside the FMU: a faster rise
parameters = Kq = 1 an error: the FMU has no such parameter
ECU_fmu sample_time = 0.02 the FMU runs two internal steps per communication step: a 20 ms lag, and the difference grows to 25°
uv run python -c "from fmpy import dump; dump('examples/generated/ECU.fmu')" the FMU's description: variables, value references, platforms

See C code generation for the details of the export.

Next