Tutorial: Sensor fault diagnosis and substitute values¶
| You will learn | range checks on a sensor signal, open circuit and short to ground (P0117/P0118), debouncing, substitute values for limp-home, fault injection in a test |
| Before this | An NTC temperature sensor interface |
| Level and time | intermediate, about 30 minutes |
| Follow along | start the editor (uv run nervus), File ▸ Open examples/ntc_sensor.nervus, press ▶ and double-click the scopes; the figures below come from the same model |
| Topic | ECU software, communication and diagnostics ▸ Diagnostics (all tutorials) |
Sensors and their wiring fail: a connector corrodes open, a chafed wire touches the engine block. The ECU must
notice, store a trouble code, and keep the engine running with a sensible substitute value. This tutorial uses
the coolant temperature sensor of the NTC tutorial (examples/ntc_sensor.py) and breaks it.
uv run python examples/ntc_sensor.py
Range checks¶
A healthy sensor never produces every voltage: the divider keeps the signal between 0.11 V (150 °C) and 4.79 V (−40 °C). The ECU uses the rest as a diagnostic window:
| Signal | Meaning | Code |
|---|---|---|
| below 0.1 V | the signal wire is shorted to ground | P0117 engine coolant temperature circuit low |
| above 4.9 V | open circuit: broken wire or connector, the pull-up pulls the signal to 5 V | P0118 engine coolant temperature circuit high |
Each check is a Compare to Constant on the measured voltage, followed by a Diagnostic Monitor that debounces
it (5 samples of 100 ms) and stores the code. While either code is pending, a Switch gives the rest of the ECU
the substitute value T_substitute = 80 °C instead of the measurement: the fan runs, and the engine is fuelled as
if warm, which is safe for driving to a workshop.
Break the wire¶
The fault_injection block (a Python Function) sets the harness resistance to 100 MΩ (open circuit) or the
signal wire's resistance to ground to 0.05 Ω (short) at fault_time = 200 s. Set fault = 1 and run:

The voltage jumps to 5.0 V; the raw measurement reads −40 °C (the end of the table), which would make the engine
run very rich if the ECU believed it. After 5 samples the code P0118 is pending (200.6 s) and the ECU uses 80 °C.
The MIL comes on in the same drive cycle (confirm_cycles = 1: electrical faults are usually confirmed at once).
With fault = 2 the voltage drops to 0 V, the raw reading is 150 °C, and P0117 is pending at 200.6 s.
The model's three test cases check the normal warm-up and both faults; run them in the Test Manager.
Experiments¶
| Try | What you will see |
|---|---|
fault = 1, fault_time = 50 |
the open circuit during the warm-up: P0118 at 50.6 s, and from then on the ECU uses 80 °C |
| threshold = 50 on P0118 | 5 s of debouncing: the wrong −40 °C reading is used for 5 s |
V_high = 4.5 |
the window is too narrow: below about −25 °C a healthy sensor already gives more than 4.5 V, so a cold start sets a false P0118 |
T_substitute = 20 |
a cold substitute: the ECU would run the engine rich, as if it were cold; why the substitute is chosen per function |
Next¶