Skip to content

Tutorial: An NTC temperature sensor interface

You will learn a thermistor in a voltage divider, the ECU's pull-up, input filter and ADC, a conversion table, resolution over the range, why software and hardware must match
Before this Your first model: a cruise control
Level and time intermediate, about 35 minutes
Follow along start the editor (uv run nervus), File ▸ Open examples/ntc_sensor.nervus, press ▶ and double-click the scopes; the figures below come from the same model
Topic Electrics and electronics ▸ ECU hardware and PCB (all tutorials)

Coolant, intake air, oil, fuel and battery temperatures are all measured the same way: an NTC thermistor in a voltage divider, read by the ECU's analog-to-digital converter. examples/ntc_sensor.py models the whole chain, from the component on the engine to the number in the software, so you can see the design decisions an ECU hardware engineer makes.

uv run python examples/ntc_sensor.py

The circuit

Part Where Value
NTC thermistor in the engine 2 kΩ at 25 °C, β = 3600 K (the Thermistor block)
harness the wiring 0.5 Ω (a Variable Resistor, used for fault injection)
sensor supply ECU board 5 V reference
pull-up resistor ECU board 2.49 kΩ
input filter ECU board 10 kΩ and 100 nF (τ = 1 ms): protection against noise and transients
ADC microcontroller 12 bits on 0-5 V (4096 counts), read every 100 ms

The NTC's resistance falls steeply with temperature, \(R = R_{25}\, e^{\beta (1/T - 1/298\,\mathrm{K})}\): 30.7 kΩ at −30 °C, 2.0 kΩ at 25 °C, 230 Ω at 90 °C. With the pull-up it forms a divider:

\[ V_{sig} = 5\,\mathrm{V} \cdot \frac{R_{NTC}}{R_{NTC} + R_{pull}} \]

The software turns the ADC counts back into a temperature with a lookup table (23 points from −40 to 150 °C, computed from the divider, the way a sensor supplier's data sheet gives it), every 100 ms.

Accuracy depends on the temperature

Signal voltage and resolution for three pull-up resistors

The divider is nonlinear, so one ADC count means a different temperature step at each temperature. With the 2.49 kΩ pull-up:

Temperature NTC Signal Resolution
−30 °C 30.7 kΩ 4.62 V 0.06 °C per count
20 °C 2.46 kΩ 2.48 V 0.02 °C per count
90 °C 230 Ω 0.42 V 0.12 °C per count
120 °C 108 Ω 0.21 V 0.26 °C per count

The pull-up is chosen so the sensor is most accurate where it matters (here 20-100 °C) and the signal stays inside the diagnostic window of 0.1-4.9 V over the whole range. Run the model: over the warm-up from −10 to 95 °C the ECU reads the temperature within 0.3 °C. (At the very first sample, at power-up, the filter capacitor is still empty and the ADC reads 0 V; real ECUs wait a few milliseconds before the first reading.)

Experiments

Try What you will see
R_pull = 470 the ECU reads 41.5 °C at 95 °C: the table still describes the 2.49 kΩ circuit. Software and hardware must match
R_pull = 470 and the table for it: in the Console, import sys; sys.path.insert(0, "examples"); from ntc_sensor import table, then model.workspace["adc_counts_axis"], model.workspace["adc_temp_table"] = table(470) accurate again (0.4 °C) and better at high temperatures, but −30 °C would give 4.92 V, above the 4.9 V open-circuit limit: a false code on a cold morning
C_filter = 100e-6 (τ = 1 s) a slower filter: the reading lags by about a second and the error grows to 0.9 °C during the warm-up

The same circuit with a short or an open wire is the subject of the next tutorial, Sensor fault diagnosis.

Next

Next in this topic: The injector driver power stage. Or pick another one from the tutorial overview.