Skip to content

Tutorial: Position control of a mass-spring-damper

You will learn what the P, I and D terms do, natural frequency and damping ratio, steady-state error, actuator limits and anti-windup
Before this Your first model: a cruise control
Level and time beginner, about 30 minutes
Follow along start the editor (uv run nervus), File ▸ Open examples/mass_spring_damper_pid.nervus, press ▶ and double-click the scopes; the figures below come from the same model
Topic Control engineering ▸ Classic lab experiments (all tutorials)

examples/mass_spring_damper_pid.py is the first experiment of many control lab courses: a mass on a spring, pushed by a force actuator, and a PID controller that moves it to a reference position. You will design the controller in the classic order, P, then PD, then PID, and see what each term does.

uv run python examples/mass_spring_damper_pid.py

The plant

A mass \(m\) on a spring \(k\) with viscous damping \(c\), pushed by a force \(F\):

\[ m \ddot x + c \dot x + k x = F \]

With \(m = 1\) kg, \(c = 0.5\) N·s/m and \(k = 2\) N/m the open plant has the natural frequency \(\omega_n = \sqrt{k/m} = 1.41\) rad/s and the damping ratio \(\zeta = c / (2\sqrt{km}) = 0.18\): left alone it oscillates for a long time. In the model the equation is two Integrators (acceleration → velocity → position) with the spring and damper as feedback Gains, the way it is drawn in every textbook. The actuator is limited to ±50 N (the PID block's upper and lower).

Step 1: P control

In the Model Workspace set Ki = 0 and Kd = 0, then press ▶ and open the scope. A P controller acts like an extra spring: the closed loop has the stiffness \(k + K_p\), so

\[ x_\infty = \frac{K_p}{k + K_p} = \frac{40}{42} = 0.952 \text{ m}, \qquad \omega_n = \sqrt{\frac{k + K_p}{m}} = 6.5 \text{ rad/s}, \qquad \zeta = \frac{c}{2\sqrt{m(k+K_p)}} = 0.04 \]

The mass shoots to 1.8 m and rings for many seconds around 0.952 m. A stiffer controller makes the error smaller but the oscillation worse: P alone cannot do both.

Step 2: PD control

Set Kd = 8. The derivative term acts like an extra damper: \(\zeta = (c + K_d) / (2\sqrt{m(k+K_p)}) = 0.66\). The overshoot drops to 5.5 % and the mass is settled within 1.4 s, but still at 0.952 m: the D term does nothing at standstill, so the steady-state error stays. The step makes the D term kick: the force jumps to the 50 N limit for a moment.

Step 3: PID control

Set Ki = 30. The integral term keeps pushing while there is any error, so the mass ends exactly at 1 m. The price is a little more overshoot (12 %); the response settles within 2 % in 2.3 s.

Controller Highest position Final position Settled (2 %)
P (Kp = 40) 1.80 m 0.952 m (still ringing at 10 s) > 10 s
PD (Kd = 8) 1.00 m 0.952 m 1.4 s
PID (Ki = 30) 1.12 m 1.000 m 2.3 s

The controller uses clamping anti-windup: while the force is at its limit, the integrator stops. With back-calculation anti-windup and Ki = 0, the integrator would still collect the saturation correction and leave a permanent offset (Simulink behaves the same way), so clamping is the right choice for a lab where the I term is switched off and on.

Check it by hand, then with the tuner

The PD loop's characteristic equation is \(m s^2 + (c + K_d) s + (k + K_p) = 0\), that is \(s^2 + 8.5 s + 42 = 0\), with the poles \(-4.25 \pm 4.9j\): \(\omega_n = 6.5\) rad/s and \(\zeta = 0.66\), as in step 2. For a systematic design open Analysis ▸ Linear Analysis ▸ PID Tuning, choose the block pid and a phase margin, and press Tune: it designs the gains from the plant the controller sees (see Linear analysis). Copy its gains into the workspace and compare its step response with yours in the Data Inspector: a large phase margin gives a calm but slower response.

Experiments

Try What you will see
Kp = 100 (PID) faster (settled in 1.3 s) but 20 % overshoot
Ki = 100 the error disappears faster, but the overshoot grows to 33 %
m = 3 (a heavier mass, same gains) 42 % overshoot: gains are tuned for one plant
Kd = 20 more damping in the PD part, but the I term still overshoots (13 %) and settling takes longer (4.5 s)

Next