Verification: coverage, requirements and the Model Advisor

Model coverage

Passing tests only say something if they exercise the model. Model coverage measures which decision outcomes the tests reached:

Block Outcomes
Switch input 0 passed, input 2 passed
Relational Operator, Compare To Constant, Logical Operator true, false
Saturation, Dead Zone below, within, above
Integrator, PID (with limits) at upper limit, at lower limit, between limits
Relay on, off
Rate Limiter rising limited, falling limited, not limited
1-D Lookup Table each interval between breakpoints, below and above the range
State Chart every state, every transition

The Test Manager measures coverage on every run and shows it next to the buttons (Coverage 50 %). Coverage report opens an HTML report listing every block with its outcomes, exercised (green, with counts) or never reached (red). A red outcome usually means a missing test case. For example, the idle speed example's tests never drive the controller to its upper limit, so no test checks full-throttle authority.

From Python:

from nervus import load
from nervus.coverage import Coverage
from nervus.testing import run_tests

model = load("examples/idle_speed_control.nervus")
cov = Coverage()
run_tests(model, coverage=cov)
print(cov.summary())  # Decision coverage: 4/8 outcomes (50 %) ...
cov.save_html("coverage.html")

simulate(model, coverage=cov) measures a single run. One Coverage object can collect several runs.

Condition coverage and MC/DC

Decisions with several conditions, the Logical Operator block with two or more inputs (enable AND speed_ok AND no_fault), are measured more strictly as well:

Measure Satisfied when
condition coverage every condition was true at least once and false at least once
MC/DC (modified condition/decision coverage) for every condition, two evaluations that differ only in that condition gave different results: each condition is shown to change the decision on its own

MC/DC is what ISO 26262 recommends for the most critical software (ASIL D) and DO-178C requires for level A. It finds tests that look complete but are not: 000 and 111 make every condition of a three-input AND true and false (100 % condition coverage) but show none of them independently (0 % MC/DC). The minimal set for an AND of n conditions is n + 1 evaluations: all true, and each condition false on its own (111, 011, 101, 110).

The Test Manager shows MC/DC next to the coverage, and the coverage report lists each decision with the conditions shown (green) and, for the others, the evaluation a test still needs, for example:

permit: condition 2: needs (1, 0, 1) → 0 (the pair (1, 1, 1) → 1 / (1, 0, 1) → 0)

State chart transition guards with several conditions count as decisions too, named after the transition (modes: crank -> idle); nested guards such as a > 0.5 and (b > 0.5 or not c > 0.5) are evaluated exactly, so masking is taken into account (with c false, b cannot change the result, and the report asks for an evaluation with c true).

From Python: cov.mcdc_percent, cov.condition_percent, cov.mcdc_missing().

Requirements traceability

ECU software is written against requirements ("the engine idles at 800 ± 50 rpm when warm"), and a review asks for each one: which part of the model implements it, and which test shows that it works? The Requirements tab (next to the Test Manager) keeps that link.

  1. Add requirements: press Add and type the id, title and text in the table, or Import CSV… a file exported from Excel, DOORS, Polarion or Jira. The file needs an id column; title (or name), text (or description) and source are optional, and both , and ; separators work.
  2. Link blocks: right-click a block (usually an ECU subsystem) ▸ Requirements… and tick the requirements it implements.
  3. Link test cases: in the Test Manager's test editor, list the ids in the Requirements field.
  4. Run the tests (Ctrl+T). Each requirement's status updates:
Status Meaning
verified it has test cases and all of them passed
failed a test case linked to it failed
not run it has test cases that have not run yet
not tested a block implements it, but no test case checks it
not implemented no block is linked to it

Report… writes the traceability matrix as an HTML page for reviews; double-click a row to show its block. Renaming a requirement's id updates the links in blocks and test cases. The Model Advisor warns about requirements without blocks or tests, and about links to ids that do not exist. Requirements are saved in the model file.

from nervus.core.requirements import Requirement, read_csv, trace, write_report
from nervus.testing import run_tests

for req in read_csv("requirements.csv"):
    model.requirements.add(req)
model.block("ECU").meta["requirements"] = ["IDLE-01", "IDLE-02"]
model.tests[0].requirements = ["IDLE-02"]
results = {r.case.name: r.passed for r in run_tests(model)}
for row in trace(model, results):
    print(row.requirement.id, row.status)
write_report(model, "traceability.html", results)

Model Advisor

Analysis → Model Advisor (⇧⌘A / Ctrl+Shift+A) checks the model for practices that often cause bugs in ECU software. Click a finding to open the block.

Rule Checks for
float-equality == / != on floating-point signals
division Product blocks that divide (possible division by zero)
antiwindup PI controllers with output limits but no anti-windup, or an integral term without limits
implicit-sampling discrete blocks that read a continuous signal without a Zero-Order Hold
chart-unreachable chart states that can never become active
chart-shadowed chart transitions that come after an always-true transition
lookup-extrapolation lookup tables that extrapolate linearly beyond the calibrated range
workspace-docs workspace variables without a unit or description (they end up in the A2L file)
workspace-unused workspace variables no block uses
default-names blocks inside subsystems that still have default names
from nervus.advisor import advise

for finding in advise(model):