Skip to content

Tutorial: Balancing an inverted pendulum with state feedback

You will learn an unstable plant, state-space models, LQR state feedback, non-minimum-phase behaviour, redesigning a gain in the Console
Before this DC motor speed and position control
Level and time advanced, about 45 minutes
Follow along start the editor (uv run nervus), File ▸ Open examples/inverted_pendulum.nervus, press ▶ and double-click the scopes; the figures below come from the same model
Topic Control engineering ▸ Classic lab experiments (all tutorials)

examples/inverted_pendulum.py is the classic advanced control lab: a pendulum hinged on a cart, balanced upright by moving the cart. Upright is unstable, a single PID loop cannot hold the pendulum and the cart at the same time, so the controller feeds back all four states with a gain designed by LQR (linear quadratic regulator). The dimensions are those of a common lab rig.

uv run python examples/inverted_pendulum.py

The plant

A cart of 0.94 kg carries a pendulum rod (0.23 kg, 0.64 m) on a hinge; the motor pushes the cart with up to ±10 N. The state is \(x = [\,x_{cart},\ \theta,\ \dot x_{cart},\ \dot\theta\,]\) with \(\theta = 0\) upright. The model uses the full nonlinear equations of motion (the cart_pole Python Function block; its integrator holds the four states):

\[ (M + m)\ddot x + m l (\ddot\theta\cos\theta - \dot\theta^2 \sin\theta) = F - b\dot x, \qquad (J + m l^2)\ddot\theta + m l \ddot x \cos\theta = m g l \sin\theta - B\dot\theta \]

Linearized at upright, \(\dot x = A x + B F\) has the poles 0, −3.8, −6.7 and +4.9 rad/s: the pendulum falls with a time constant of 0.2 s. Set K_lqr to [0, 0, 0, 0] and run: it falls past 0.5 rad (29°) within 0.6 s.

The controller: LQR state feedback

State feedback \(F = -K(x - x_{ref})\) places all four poles at once. LQR chooses the \(K\) that minimizes

\[ J = \int_0^\infty \left( x^T Q x + r F^2 \right) dt, \qquad Q = \mathrm{diag}(q_x, q_\theta, 0, 0) \]

so \(q_x\) and \(q_\theta\) say how much cart and angle errors cost, and \(r\) how much force costs. lqr_gain() in the example solves the Riccati equation (with SciPy) for the linear model; with \(q_x = 50\), \(q_\theta = 100\), \(r = 1\) it gives \(K = [-7.1,\ -57,\ -15,\ -11]\), stored in the workspace as K_lqr and used by the K gain block (matrix multiplication). The sensors are sampled every 2 ms.

Run the model: the controller catches the 3° start, rejects the tap at 3 s (5 N for 0.1 s) and moves the cart to 0.3 m at 5 s, settling within 2 % in 3.6 s, with the pendulum never more than 3° from upright and at most 4.3 N.

Look at the cart at 5 s, when the reference jumps to +0.3 m: it first moves backwards (from −17 to −26 mm, it was still recovering from the tap) and the pendulum leans 2° towards +x before the cart follows. To move right, the pendulum must first lean right, and the only way to tip it is to pull the cart left from under it. This non-minimum-phase behaviour (a zero in the right half plane) is why balancing systems react "backwards", and why they cannot be made arbitrarily fast.

Redesign the gain in the Console

K_lqr is a workspace variable, so a new design is one line in the Console tab:

import sys

sys.path.insert(0, "examples")
from inverted_pendulum import lqr_gain

model.workspace["K_lqr"] = lqr_gain(q_x=200)

Then press ▶ and compare the runs in the Data Inspector.

Experiments

Try What you will see
lqr_gain(q_x=200) the cart is more important: it reaches 0.3 m in 2.1 s instead of 3.6 s, the pendulum leans up to 3.8°
lqr_gain(r=10) force is expensive: gentle and slow, the cart has only reached 0.25 m after 5 s
F_max = 3 a weaker motor still balances (it saturates for a moment during the tap)
F_max = 1.5 too weak for the tap: the pendulum falls at 3.7 s
m_pend = 0.35 the plant is heavier than the design model, and the LQR gain is robust enough to balance it anyway

Next

That was the last tutorial on control engineering. Continue with powertrain and engine control: Engine operating modes, or pick another one from the tutorial overview.