Skip to content

Concepts

Signals

Every signal is a vector of floating-point numbers. A scalar signal has width 1. Widths are worked out automatically when the model is compiled. Most math blocks work elementwise, and a scalar combines with a vector by scalar expansion (a scalar gain of 2 doubles every element).

Blocks

A block is a small dynamic system with inputs u, outputs y and optionally states x:

Function Meaning Called
outputs(t, u, xc, xd) output equation \(y = g(t, u, x)\) whenever outputs are needed
derivatives(t, u, xc, xd) continuous states \(\dot x_c = f(t, u, x_c)\) by the solver
update(t, u, xc, xd) discrete states \(x_d[k+1] = f(t, u, x_d[k])\) at the block's sample hits

Direct feedthrough means that outputs uses u directly (Gain, Sum). Blocks whose output only depends on their state (Integrator, Unit Delay) are not direct feedthrough.

Execution order and algebraic loops

Before simulating, Nervus sorts the blocks so that each direct-feedthrough block runs after the blocks that drive it. A feedback loop made only of direct-feedthrough blocks has no valid order. That is an algebraic loop: \(y = u - 2y\) defines y in terms of itself. Nervus reports these as errors and lists the blocks involved:

AlgebraicLoopError: algebraic loop: s -> g -> s. Every feedback loop needs a block with state ...

Put an Integrator (continuous) or a Unit Delay (discrete) in the loop. In a real control system that delay always exists anyway.

Solving algebraic loops

Some models are naturally algebraic: a voltage divider with a load that depends on its own voltage, a mass-flow balance, a controller with a direct feedthrough on purpose. For these, set Simulation ▸ Settings ▸ Algebraic loops to Solve iteratively (in Python: model.settings.algebraic_loops = "solve"). Nervus then

  1. finds each loop (a group of blocks that depend on each other directly),
  2. chooses tear blocks in it, whose outputs it guesses, so that the rest of the loop can be computed in order,
  3. adjusts the guess with Newton's method until computing the loop from the guess gives the guess back: for \(y = u - 2y\) it finds \(y = u/3\), and for \(x = \cos x\) it finds 0.739085.

Each evaluation of the model then solves the loop, which is slower; the simulation reports every solved loop as a warning, with its tear blocks. A loop without a solution (e.g. \(y = u + y\) with \(u \ne 0\)) stops the simulation with an error naming the blocks. A loop must run at one rate and outside enabled or triggered subsystems, and a model with a solved loop cannot become C code: an ECU cannot iterate in its tasks, so break the loop with a Unit Delay before generating code.

Sample times

Each block runs at a sample time, using the same values as Simulink:

Value Meaning
0 continuous: computed at every solver step
T > 0 discrete: computed every T seconds, held in between
[T, offset] discrete with an offset
-1 inherited from the blocks that drive it
inf constant: computed once

Inherited blocks take the sample time of their inputs: a Gain after a 10 ms Zero-Order Hold also runs every 10 ms. If its inputs have mixed rates it becomes continuous.

Discrete outputs are computed only at sample hits and held between them. That is how code on an ECU behaves: a 10 ms task computes a value and it stays put until the next run.

Use a Zero-Order Hold where a continuous signal (a sensor) enters a discrete controller.

Solvers

Solver Type Use for
auto / RK45 variable step the default; smooth, non-stiff models
RK23 variable step low accuracy needs, quick
DOP853 variable step high accuracy
Radau, BDF, LSODA variable step, implicit stiff models (very fast and very slow dynamics together)
rk4 fixed step models that will become code; deterministic step size
euler fixed step the simplest method; matches simple embedded code

Variable-step solvers pick their own step size from rtol/atol, up to max_step. They also stop exactly at discontinuities that blocks announce (the time of a Step, the edges of a Pulse), so these are captured accurately.

Fixed-step solvers use step everywhere. The step must divide every discrete sample time. If you don't set it, Nervus picks one.

Zero crossings and discontinuities

Switching inside a model, such as a Saturation hitting its limit, a Switch changing input, an Integrator reaching its limit or a comparison flipping, makes the equations discontinuous. Variable-step solvers cannot step across a discontinuity accurately, so Nervus uses zero-crossing detection (like Simulink):

  1. Each such block declares a zero-crossing signal that changes sign exactly at the discontinuity, e.g. u − upper for a saturation.
  2. During integration the block's branch (its mode, e.g. "saturated at the upper limit") is frozen, so the equations stay smooth.
  3. The solver stops exactly where a zero-crossing signal changes sign, and the modes are re-evaluated there.

The result is exact switching times and accurate integrals, e.g. ∫ clip(sin t) to 1e-8 with large steps. If a signal keeps crossing back and forth very rapidly (the system chatters along a limit), detection is switched off for that block and the run reports a warning in Diagnostics.

Turn it off in Simulation Settings (Locate discontinuities exactly) or with d.settings.zero_crossing = False. Fixed-step solvers never use it: on an ECU the code also just steps.

Blocks with zero crossings: Saturation, Dead Zone, Abs, Sign (Math Function), Switch, Relational Operator, Compare To Constant, Integrator (with limits), PID Controller (with limits). Stop Simulation stops a run at the exact moment its input becomes true, and Assertion fails it when its input becomes false.

Simulation loop

At each major step Nervus (1) computes all outputs, (2) logs them, (3) updates discrete states with a sample hit, and (4) integrates the continuous states to the next major step. With a variable-step solver, the major steps are the discrete sample hits and the breakpoints. The solver's own steps in between are logged too.

Accelerated simulation

Simulation Settings → Simulation mode → Accelerated runs the whole model as compiled C: Nervus generates C code for every block, compiles it, and runs the simulation loop in C. Large models run 30 to 700 times faster. The first run of a model (and the first run after a parameter change) takes a moment longer to compile; later runs use the compiled code again.

Normal Accelerated
Blocks all blocks with C code: the ECU blocks, Integrator, Transfer Fcn, State-Space, Derivative, PID, the time sources (Step, Sine, Pulse, Ramp, From Workspace, Drive Cycle, Clock) and Python Function blocks written in simple Python
Solver the one you chose the fixed-step solver you chose; a variable-step solver is replaced by rk4 (the step is the max step, else 1/1000 of the time span)
Needs nothing a C compiler (on macOS: xcode-select --install; on Linux: gcc; on Windows: MinGW or clang)

The results are the same as a normal run with the same fixed-step solver (to about 1e-12). Models with blocks that have no C code (physical networks, FMUs, CAN buses, OBD Responder), algebraic loops, or coverage collection run normally, and Diagnostics says why. A Python Function is translated if it uses numbers, if/elif/else, arithmetic, math/np functions, min/max/abs, np.clip and np.interp with lists of numbers; loops and arrays keep the model in normal mode. In Python:

d.settings.mode = "accelerated"
res = simulate(d)
print(res.stats.solver)  # "rk4 (accelerated, compiled C)"