Skip to content

Subsystems

A subsystem is a block that contains its own diagram. Subsystems structure a model the way functions structure code. In ECU work, each subsystem is typically one software function (throttle control, fuel, ignition), and the generated C code will follow that structure.

Here the throttle example is grouped so that everything running on the ECU (sensor sampling, error and PI controller) is inside one subsystem:

The throttle model with an ECU subsystem

Double-click it to open it. The breadcrumb bar shows the path back to the model:

Inside the ECU subsystem

In the editor

Action How
Group blocks into a subsystem select them, Edit → Create Subsystem from Selection (⌘G / Ctrl+G)
Open a subsystem double-click it
Go back up click a breadcrumb, or View → Up to Parent (⌘↑ / Ctrl+Up)
Add an empty subsystem Library → Ports & Subsystems → Subsystem

Lines crossing the selection boundary become In/Out ports. Undo works across levels and opens the subsystem where the change is undone.

Atomic subsystems: one ECU task

An ECU's operating system runs its software in tasks with fixed periods, such as a 10 ms task for idle speed and throttle control and a 100 ms task for temperatures. In Nervus, a subsystem with a sample_time is such a task:

A 10 ms and a 100 ms task

  • Every block inside that inherits its sample time (-1, e.g. Gain, Sum, Counter, Discrete PID with sample_time = -1) runs at the task period. Blocks with their own sample time keep it, and an inner task keeps its own period.
  • The inputs are sampled at the start of each period and the outputs held until the next one, as if the task read its inputs from RAM when it starts.
  • Blocks with continuous states (Integrator, Transfer Function) are not allowed inside. Use their discrete versions.
  • The block shows its period (⏱ 10 ms). In generated C the multirate scheduler runs each task's blocks at its rate, or, with one function per task, each task becomes its own C function (see C code generation).

So you set the period in one place, and every block in the task follows it: change sample_time to "Ts_fast" and the whole task moves with the workspace variable.

Enabled subsystems

Tick enable_port in a subsystem's Properties to give it an extra last input, ⏻ enable. While the enable is ≤ 0 nothing inside runs: outputs and discrete states are held, and continuous states stop. Typical use: a function that only runs in one operating mode, with the enable coming from a State Chart's mode output.

when_enabled Discrete states when enabled again
held (default) continue from where they stopped
reset restart from their initial values

The enable is decided once per time step (when the blocks inside execute) and held during solver sub-steps. The generated C wraps the subsystem's blocks in if (enabled) and resets their states the same way, which the test suite checks against the simulation with zero tolerance.

Triggered subsystems

Set trigger to rising, falling or either to give the subsystem a last input, trigger. The subsystem then runs only when that signal has an edge, and holds its outputs and states in between. Use it for event-driven functions: counting crank teeth, latching a value when a button is pressed, or running a task each time a CAN message arrives.

A subsystem with an enable and a rising-edge trigger input

trigger Runs when the trigger signal goes
rising from ≤ 0 to > 0
falling from > 0 to ≤ 0
either either way

The trigger is checked each time the blocks inside would execute, so drive it with a discrete signal of the same rate as those blocks. The first execution only records the trigger value, so nothing runs before the first real edge. Blocks with continuous states (integrators, transfer functions) are not allowed inside; use their discrete versions. A subsystem can have both an enable and a trigger input (data inputs first, then enable, then trigger). It then runs on an edge only while it is enabled. The generated C checks the edge the same way, and the tests compare it with the simulation with zero tolerance.

Variant subsystems: several implementations of one component

A subsystem can have variants: alternative implementations with the same inputs and outputs. Typical uses: a petrol and a diesel engine model, a simple and a detailed sensor model, or the controller for two vehicle versions. Only the active variant is simulated and turned into C code.

Select a subsystem and press Create Variants… (or Variants…) in the Properties panel:

The Variants dialog

  • Add (copy of active) creates a new variant as a copy of the active one; open the subsystem and change it.
  • Condition chooses the variant from model workspace variables, e.g. ENGINE == 2. Comparisons (==, !=/~=, <, <=, >, >=) and and/&&, or/||, not/~ are allowed. A variant with an empty condition is the default, used when no condition is true. It is an error if several conditions are true at once.
  • Without any conditions, you pick the active variant by hand.

The block shows the active variant (◆ petrol). Opening the subsystem shows and edits the active variant; switch variants to edit another. A parameter sweep can switch variants too: simulate(model, 10, params={"ENGINE": 2}).

A variant subsystem

engine = Subsystem(system=petrol_engine)
engine.active_variant = "petrol"
engine.add_variant("diesel", diesel_engine, condition="ENGINE == 2")
engine.variants["petrol"].condition = "ENGINE == 1"

Function-call subsystems

Sometimes logic, not a clock, decides when a function runs: store a value each time the engine is switched off, or run a learning routine once per drive cycle. Set trigger to function_call: the subsystem then runs once every time the trigger value changes. The caller, usually a State Chart, increments a counter output whenever it wants the function to run:

input u
output calls = 0

state low
state high
  entry: calls = calls + 1      # call the subsystem once, every time we enter "high"

transition low -> high: u > 0.5
transition high -> low: u < -0.5

Connect calls to the subsystem's trigger input (marked ƒ()). The subsystem runs in the same time step as the call, after the chart, and holds its outputs and states between calls. In generated C it becomes if (call counter changed) { ... } around its blocks.

Masks: reusable components with parameters

A masked subsystem has its own parameters, like a function's arguments. The blocks inside use them in their expressions, and each copy of the subsystem can have different values. This is how you build reusable components such as an engine model with a displacement parameter.

Select a subsystem and press Create Mask… (or Edit Mask…) in the Properties panel:

The Edit Mask dialog

  • Mask parameters: name, value, unit and description. Values can be numbers, vectors, or expressions of model workspace variables (3 * base).
  • Icon text: shown on the block; \n starts a new line.
  • Description: shown in the Properties panel.

The parameters then appear in the Properties panel of the subsystem, like the parameters of any block:

A masked subsystem and its parameters

Names are looked up from the inside out: a block sees the parameters of the nearest mask first, then those of outer masks, then the model workspace. In generated C, mask parameters are per-instance values. Only bare model workspace variables become shared calibration parameters.

from nervus.core import Variable

engine = Subsystem(system=engine_diagram)
engine.mask.add(Variable("displacement", 1.6e-3, "Swept volume", "m³"))
engine.mask_icon = "Engine\\n1.6 l"

In Python

from nervus import Diagram, simulate
from nervus.blocks import Gain, Inport, Integrator, Outport, Scope, Step, Subsystem, Sum

plant = Diagram("plant")
u = plant.add(Inport(port=1), name="u")
e = plant.add(Sum(signs="+-"), name="e")
k = plant.add(Gain(gain="1/tau"), name="k")  # uses the model workspace
y = plant.add(Integrator(), name="y")
plant.connect(u, (e, 0))
plant.connect(y, (e, 1))
plant.chain(e, k, y, plant.add(Outport(port=1), name="y_out"))

model = Diagram("model")
model.workspace["tau"] = 0.5
sub = model.add(Subsystem(system=plant), name="plant")
model.chain(model.add(Step(time=0.0)), sub, model.add(Scope()))

res = simulate(model, 2.0)
res["plant/y"]  # blocks inside subsystems are named by path

How it works

Before simulation, the compiler flattens the hierarchy. The In and Out blocks inside subsystems become identity nodes, so sorting, signal widths and sample times work across subsystem boundaries exactly as in a flat model. Every block keeps its path name for results and error messages.

In model files, a subsystem block carries its diagram in a nested "system" entry (schema version 3).