Skip to content

Tutorial: DC motor speed and position control

You will learn system identification from a step response, PI design by pole-zero cancellation, PD design from damping and natural frequency, a physical motor model and a 1 kHz controller
Before this Position control of a mass-spring-damper
Level and time intermediate, about 45 minutes
Follow along start the editor (uv run nervus), File ▸ Open examples/dc_motor_speed.nervus, examples/dc_motor_position.nervus, press ▶ and double-click the scopes; the figures below come from the same model
Topic Control engineering ▸ Classic lab experiments (all tutorials)

examples/dc_motor_lab.py is the servo experiment of control lab courses: a small DC motor with an inertia disk, a ±10 V amplifier, an encoder, and a controller running at 1 kHz. You will identify the motor from a step response, design a PI speed controller by pole-zero cancellation, and a PD position controller from a damping specification. The motor data are those of a typical teaching rig.

uv run python examples/dc_motor_lab.py    # builds dc_motor_speed.nervus and dc_motor_position.nervus

The plant

The motor is built from physical blocks: the amplifier is a controlled voltage source, the DC motor block has the armature resistance \(R = 8.4\) Ω, inductance \(L = 1.16\) mH and torque constant \(k_m = 0.042\) N·m/A, and the shaft drives an inertia \(J = 2.1 \cdot 10^{-5}\) kg·m². The encoder (an angle sensor) and a speed sensor feed the 1 ms controller through Zero-Order Holds. Neglecting the small inductance, voltage to speed is a first-order system:

\[ \frac{\omega(s)}{V(s)} = \frac{K}{\tau s + 1}, \qquad K = \frac{1}{k_m} = 23.8 \ \tfrac{\text{rad/s}}{\text{V}}, \qquad \tau = \frac{R J}{k_m^2} = 0.10 \text{ s} \]

Step 1: identify the motor

Open dc_motor_speed.nervus, set closed_loop = 0 in the Model Workspace and run: the amplifier gets a 5 V step at 0.1 s. In the scope, read the final speed (119 rad/s, so \(K = 119 / 5 = 23.8\) rad/s/V) and the time at which the speed reaches 63 % of it: 0.1 s after the step, so \(\tau = 0.10\) s. This is how you would identify the real rig, and the numbers match the formulas above.

Step 2: PI speed control

Set closed_loop = 1. A PI controller \(C(s) = K_p + K_i/s = K_p (1 + \frac{1}{T_i s})\) with \(T_i = \tau\) cancels the motor's pole; the loop then behaves like an integrator \(K K_p / (\tau s)\), and the closed loop is first order with the time constant \(\tau_{cl} = \tau / (K K_p)\). For \(\tau_{cl} = 33\) ms:

\[ K_p = \frac{\tau}{K \tau_{cl}} = 0.122 \ \tfrac{\text{V}}{\text{rad/s}}, \qquad K_i = \frac{K_p}{\tau} = 1.26 \ \tfrac{\text{V}}{\text{rad}} \]

Run it: the speed follows the 50 rad/s step like a first-order system (63 % after 34 ms), without overshoot, and the amplifier needs 6.1 V at most. Set Ki_w = 0 to see why the I term is there: with P alone the motor settles at 37.2 rad/s, because the steady state needs a voltage and P only gives one when there is an error (\(50 \cdot K K_p / (1 + K K_p)\)).

Step 3: PD position control

Open dc_motor_position.nervus. From voltage to angle the motor adds an integrator, \(\theta(s)/V(s) = K / (s(\tau s + 1))\). With a PD controller \(V = K_p e + K_d \dot e\) the closed loop is

\[ \tau s^2 + (1 + K K_d) s + K K_p = 0 \quad \Rightarrow \quad \omega_n^2 = \frac{K K_p}{\tau}, \qquad 2 \zeta \omega_n = \frac{1 + K K_d}{\tau} \]

For \(\omega_n = 40\) rad/s and \(\zeta = 0.7\): \(K_p = 6.5\) V/rad and \(K_d = 0.186\) V·s/rad. The 1 rad step overshoots by 4.3 % (the textbook value for ζ = 0.7 is 4.6 %) and is settled within 2 % after 0.14 s. The step makes the D term kick the amplifier to its 10 V limit for a moment. Set Kd_th = 0 to see the undamped servo: 70 % overshoot and a long ringing.

Experiments

Try What you will see
speed: Kp_w = 0.5, Ki_w = 5.15 faster (63 % after 14 ms), but the amplifier saturates at 10 V
speed: J = 4.2e-5 (a heavier disk) the cancellation no longer fits: slower (57 ms) and 8 % overshoot
position: Kd_th = 0.05 too little damping: 42 % overshoot
position: Kp_th = 20 faster but 25 % overshoot; the amplifier limits the acceleration
position: J = 4.2e-5 17 % overshoot: a controller tuned for one load does not fit another

Next

Next in this topic: Level control of coupled water tanks. Or pick another one from the tutorial overview.