Skip to content

Tutorial: Requirements-based testing and coverage

You will learn requirements imported from a CSV file, traceability from requirements to blocks and tests, model coverage to find untested behaviour, closing the gap, review reports
Before this Idle speed control
Level and time intermediate, about 40 minutes
Follow along start the editor (uv run nervus), File ▸ Open examples/idle_requirements.nervus, press ▶ and double-click the scopes; the figures below come from the same model
Topic Testing and verification (all tutorials)

In the automotive industry a function is finished when every requirement is verified by a test, and the tests exercise the whole function (coverage). This tutorial takes the idle speed controller of the idle speed tutorial through that process: import its requirements, link them to the model and the tests, find the gap, close it, and write the reports a review asks for.

uv run python examples/idle_requirements.py   # the finished result: idle_requirements.nervus and two reports

Step 1: import the requirements

The requirements of the function are in examples/data/idle_requirements.csv, as exported from a requirements tool or a spreadsheet (;-separated, with id, title, text and source columns):

Id Title Requirement
IDLE-01 Idle speed With the engine warm and no load change, the idle speed stays within 800 ± 20 rpm.
IDLE-02 Load rejection When the AC compressor switches on, the speed drops by less than 50 rpm and is back within ± 20 rpm after 4 s.
IDLE-03 Stall protection Even without the AC feed-forward the engine must not stall: the speed stays above 600 rpm.
IDLE-04 Calibratable target The idle target is a calibration parameter; the engine reaches a new target within ± 15 rpm.
IDLE-05 Limited correction The correction is limited to 15° of throttle, and a large target change still settles without windup.

Open examples/idle_speed_control.nervus, go to the Requirements tab and press Import CSV…. All five appear as not implemented: nothing in the model claims them yet.

  • Right-click the ECU subsystem ▸ Requirements… and tick all five: the ECU implements them. They change to not tested.
  • In the Test Manager, open each test case and fill in Requirements: AC compressor on at 5 s verifies IDLE-01 and IDLE-02, AC compressor on, no feed-forward IDLE-03, higher idle target IDLE-04.
  • Press Run All (Ctrl+T). Four requirements are now verified, and IDLE-05 is still not tested: no test checks the limit.

The requirements after the tests have run

Step 3: find what the tests miss

Requirements tell you what to test; coverage tells you whether the tests reached every decision in the model. The Test Manager measures it with every Run All: the line under the results shows the coverage, and Coverage report lists what was missed (in Python: run_tests(model, coverage=Coverage()), as in the example):

Decision coverage: 4/8 outcomes (50 %) in 3 run(s)
  ECU/idle_pi: never output at upper limit
  p_intake: never at upper limit, at lower limit
  omega: never at lower limit

The controller idle_pi never reached its upper limit, exactly the behaviour IDLE-05 is about. The other three outcomes are limits of the plant (the manifold pressure and a stopped engine): physically impossible or a stall, so they are justified in the review rather than tested.

Step 4: close the gap

Add a test case in the Test Manager:

Field Value
Name large target change: correction limited
Parameter overrides rpm_idle = 1500
Requirements IDLE-05
Checks bounds on ECU/idle_pi (lower −2, upper 15); final_value of engine_rpm = 1500 ± 20

Run all tests again: the controller now saturates at 15°, the engine still settles at 1500 rpm, IDLE-05 is verified, and the controller's decisions are fully covered (5 of 8 outcomes, the rest being the plant).

Step 5: the reports

Report… in the Requirements tab writes the traceability matrix (requirement → blocks → tests → status) as an HTML page; the coverage report lists every decision outcome. The example writes both to examples/generated/. Together with the test results they are what a design review or an ISO 26262 assessment asks for. The Model Advisor (Analysis ▸ Model Advisor) adds the static checks: it warns about requirements without blocks or tests, and about links to unknown ids.

Experiments

Try What you will see
Kp_idle = 0.01 (a weak controller), run the tests the two AC tests fail: IDLE-01, IDLE-02 and IDLE-03 show failed, IDLE-04 and IDLE-05 still pass
rename IDLE-05 to IDLE-06 in the table the links in the ECU block and the new test follow the rename
delete the link from the ECU to IDLE-03 IDLE-03 becomes not implemented, even though its test still passes

Next

Next in this topic: Robustness and tolerances with Monte Carlo. Or pick another one from the tutorial overview.